<%@ page contentType="text/html; charset=gb2312" language="java" import="java.sql.*" errorPage="" %> 沈阳中科博微自动化技术有限公司

 

 

 

NCS-PT105Ⅱ Series pressure transmitter

As a new generation of miniaturization fieldbus intelligent transmitter, NCS-PT105 series pressure transmitter is developed by using fieldbus technology on the base of common 1151 pressure transmitter. It can select FF H1,Profibus PA or HART protocol and has the characteristics of miniaturization and high precision.

Main purpose and usage range

NCS-PT105 applies to the pressure measurement of liquid, gas or steam and can measure the pressure signal of difference pressure, absolute pressure, and gauge pressure. NCS-PT105 broadly applies to production process automation field of data collection in medicine, chemical industry, metallurgy, electric power and light industry, etc.

FF/PA Protocol pressure transmitter

Main characteristic

 •  Explosion prevention, waterproof , intrinsic safety

 •  Link master device function

 •  Bus power supply function

 •  Support instantiation and delete function block

 •  Pass FF/PA physical layer conformance test

 •  Inner temperature compensation technique

 •  Software calibration

Basic parameter

Process fluid

Liquid, gas, steam

Output signal

Digital signal, Fieldbus rate 31.25kbit / s

Bus power

Bus power: 9 ~ 32 VDC

Current consumption (static) : ≤ 20mA

Display

Optional 5 digits LCD Display

Degree of protection

IP65

Explosion prevention

Intrinsic safety: explosion prevention capacity——EXiaⅡCT4

Standard

CENELEC EN 50014

CENELEC EN 50020

CENELEC EN 50039

Temperatu re limits

Operation: - 40 ~ 85℃

Storage: - 45 ~ 115℃

Humidity limits

0 to 100% relative humidity

Reliability

MTBF:10 ten thousand hours

Performance specification

Accuracy

0.075%

Stability

0.05% / year ~ 0.1% / year

Temperature

effect

± (0.02% URL+0.1% range) / 20℃

Power effect

± 0.005% calibration range / voltage

Vibration effect

IEC 6 0068-2-6 Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)

Electromagnetic

compatibility

IEC 6 1000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

IEC 6 1000-4-3 Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

IEC 6 1000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test

IEC 6 1000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

IEC 6 1000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

Range rate

50:1

HART Protocol pressure transmitter

Main characteristic

 •  Explosion prevention, waterproof , intrinsic safety

 •  Full digital——using capacitance / frequency convert technology

 •  High precision——0.075%

 •  Inner temperature compensation technique

Basic parameter

Process fluid

Liquid, gas, steam

Output signal

Digital signal ,Fieldbus rate 31.25kbit/s

Bus Power

Bus power:9 ~ 32VDC Current consumption(static): ≤20mA

Display

Optional 5 digits LCD Display

Degree of protection

IP65

Explosion prevention

Intrinsic safety: explosion prevention capacity——EXiaⅡCT4

Standard

CENELEC EN 50014

CENELEC EN 50020

CENELEC EN 50039

Temperature limits

Operation : - 40 ~ 85℃

Storage : - 45 ~ 115℃

Humidity limits

0 to 100% relative humidity

Reliability

MTBF:10 ten thousand hours

Performance specification

Accuracy

0.075%

Stability

0.05% / year ~ 0.1% / year

Temperature effect

± (0.02% URL+0.1% range) / 20℃

Power effect

± 0.005% calibration range / voltage

Vibration effect

IEC 60068-2-6 Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)

Electromagnetic

compatibility

IEC 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

IEC 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

IEC 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test

IEC 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

IEC 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

Range rate

50:1

 


© Microcyber Inc.